(905) 553-4629
195 sq.ft  120 Volt Warm Surface , Return type Radiant Floor Heating System
0 ITEM(S) IN YOUR BAG / TOTAL: C$0.00 view cart
195 sq.ft  120 Volt Warm Surface , Return type Radiant Floor Heating System
Reverse Osmosis Systems
Reverse Osmosis Systems
Home Drinking Home Drinking
Alkaline Mineral Infrared Alkaline Mineral Infrared
RO Systems with pump RO Systems with pump
RO with UV - Ultra Violet    RO with UV - Ultra Violet
Portable Mini-Max Portable Mini-Max
Reef DI & Home / Dual  Reef DI & Home / Dual
Aquarium RO.DI Aquarium RO.DI
Hydroponics RO Hydroponics RO
LCD Micro-Computer LCD Micro-Computer
RO Commercial RO Commercial
Standing - Dispenser Standing - Dispenser
Whole House Systems
Whole House Systems
20 x 4.5 Big Blue Systems 20 x 4.5 Big Blue Systems
20 x 2.5 Slim Blue Systems 20 x 2.5 Slim Blue Systems
10 x 4.5 Systems 10 x 4.5 Systems
10 x 2.5 Systems 10 x 2.5 Systems
Whole house Water Softners Whole house Water Softners
Drinking Water Purifiers
Drinking Water Purifiers
Water Filters
Water Filters
Reverse Osmosis Filters Reverse Osmosis Filters
R.O. Membranes R.O. Membranes
10 x 2.5 10 x 2.5
20 x 2.5 20 x 2.5
10 x 4.5 10 x 4.5
20 x 4.5 20 x 4.5
Inline Filters Inline Filters
Ceramic Filters Ceramic Filters
Candle Filters Candle Filters
Quick Change Filter Quick Change Filter
Shower Filters Shower Filters
Water Parts & Accessories
Water Parts & Accessories
In-Line Monitors & Testers In-Line Monitors & Testers
Faucets Faucets
Filter Housings Filter Housings
Storage Tanks Storage Tanks
Booster Pumps Booster Pumps
UV - Ultra Violet UV - Ultra Violet
R.O Accessories Parts R.O Accessories Parts
Compression Fittings Compression Fittings
Quick Connect Fittings Quick Connect Fittings
Accessory Accessory
Brakets Brakets
Water Dispensers
Water Dispensers
Water Fountains
Water Fountains
Air Filters
Air Filters
Air Filters By Model Air Filters By Model
5'' , 4'' , 3''  Air Filters 5'' , 4'' , 3'' Air Filters
1'' Air Filters 1'' Air Filters
2'' Air Filters 2'' Air Filters
Electrostatic Filters Electrostatic Filters
Media Cleaners
Media Cleaners
By Model By Model
By Size By Size
Electronic Cleaners
Electronic Cleaners
By Model By Model
By Size By Size
HEPA Air Cleaners
HEPA Air Cleaners
Humidifiers & Pads
Humidifiers & Pads
Booster Fans
Booster Fans
Speed Motor Control Speed Motor Control
Under Floor Heating
Under Floor Heating
TWIN WIRE NON-RETURN TWIN WIRE NON-RETURN
RETURN WIRE TYPE RETURN WIRE TYPE

Home > Under Floor Heating > RETURN WIRE TYPE > 120 Volt Warm Surfaces
195 sq.ft 120 Volt Warm Surface , Return type Radiant Floor Heating System
Part Number WZ-150195120
195 sq.ft  120 Volt Warm Surface , Return type Radiant Floor Heating System
Email a friend Email a friend
Review this item Review this item
Price
Your Price:  
C$420.00
Availability:
Ships within 24 hours of ordering & Directly from the factory
Send to:
or add name:
help
*We'll ask for shipping info at checkout
Quantity Price
3 - 5 C$399.00
6+ C$378.00
Quantity
Add to Wish List
Description
  
RETURN TYPE
UNDER FLOOR ELECTRIC HEATING SYSTEM

+  25  YEARS

LIMITED WARRANTY

 

Coverage Area

4" inch.   / 195 pi2/sq.ft    18.00 M2

3" inch.   / 150 pi2/sq.ft    13.5 M2

120 Volts / 1800 Watts / AMP 15
  Total ohms  8     /    Lenght  600
 

120 VOLTS

Return Wire Systems
 COVERAGE & SPACING               Resistance               

Model #

3”

12W

7.6cm 129w/m2

4”

9W

10cm

97w  /m2

Total   WATTS

Amp.

Total ohms

LENGTH

WZ- 010013120

10

0.9

13

1.2

120

1

120

40

WZ- 015020120

15

1.4

20

1.8

180

1.5

80

60

WZ- 040052120

40

3.6

52

4.8

480

4

30

160

WZ-050065120

50

4.5

65

6

600

5

24

200

WZ-055072120

55

5

72

6.5

660

5.5

23

220

WZ-068088120

68

6.2

88

8

816

6.8

18

272

WZ-075098120

75

6.8

98

8.8

900

7.5

15

300

WZ-100130120

100

9

130

12

1200

10

13

400

WZ-125163120

125

11.25

163

14.5

1500

12.5

10

500

WZ-150195120

150

13.5

195

18

1800

15

8

600

 
240 VOLTS
Return Wire Systems
 COVERAGE & SPACING               Resistance               

Model #

3”

12W

7.6cm 129w/m2

4”

9W

10cm

97w /m2

Total   WATTS

Amp.

Total ohms

LENGTH

WZ-015020240

15

1.4

20

1.8

180

0.75

330

60

WZ-050065240

50

4.5

65

6

600

2.5

90

200

WZ-100130240

100

9

130

12

1200

5

48

400

WZ-110145240

110

10

145

13

1320

5.5

47

440

WZ-136180240

136

12.2

180

16.2

1632

6.8

35

544

WZ-150195240

150

13.5

195

18

1800

7.5

31

600

WZ-170220240

170

15.3

220

20.3

2040

8.5

28

680

WZ-250325240

250

 22.5

325

29

3000

12.5

20

1000

WZ-300390240

300

27

390

36

3600

15

16

1200

CAUTION !!!

Its illegal to install a thermostat is not listed as CLASS A in the bathroom and kitchen, Your are assuming the liability....

 

Our radiant space heating panels, panel sets, and systems, with accessories are Certified by   

 

The International ENERGY STAR Symbol  Le marque international de haute efficacité ENERGY STAR    Cover Art
UL - the standard in safety
  
ISO 9001.2000
UL Listed under UL#1673
CSA C22.2 No.217-M89
UL FILE #E240867
VER 1.4

 

MADE IN CANADA
   BY
 WARM SURFACESTM
 
 

100% satisfaction guaranteed

 
What is Radiant Heat
The Suns rays are heat waves radiating from the sun, and traveling towards earth the earth absorbs the heat and you feel comfortable.
 

Floor heating systems turns your home into your personal sun. Heat radiated from the floor, traveling towards you and you furniture you absorb that heat and you are comfortable.

The amount of heat generated by the sun cannot be controlled. Floor heating systems have their own thermostat thus allowing us to be comfortable year round.

Heat travels through the air without
heating it, so your environment is always cool and comfortable.
 

 

 
 
 
Be Informed, Compare and Put the Savings in Your Pocket
 
                                 
Convection HeatRadiant Heat
Low temperature heat rays generated by the floor travel in the room like the sun heating earth. This heat is absorbed. The air is not heated, temperature is constant from floor to ceiling.
 
 
 
Energy Consumption
  • Very Low
  • 30% Cheaper than other heating methods
  • Zone Control
  • Most Efficient System.
  •  
    Comfort
    • Uniform heat. Wall to wall floor to ceiling.
    • Heat transfers directly to the person.
    • Cozy warm feet. No cold air draft.
    • Rapid response to temperature variations. Moist air.
    • Cool replacement air (from ventilation)
    Safety
    • Heating element is accessible.
    • Embedded in concrete.
    • Low temperature heat.
    • System protected from shock hazards by a GFCI.
    • Cannot be tampered with.
    • Floor temperature cannot reach more than 105°F or 40°C.
    Maintenance
    Simply No MAINTENANCE!
    Installation
    • Sketch a layout. Lay down cable, and heat probe.
    • Cover system with thin layer of concrete.
    • Connect thermostat.
    Cost
    • Modestly Expensive.
    • One time Expense.

    Convection HeatConvection Heat

    Air travels through high temperature heating element. Warm air rises to the ceiling, pushed back cold air to the floor, cold air eventually gets to the base board and gets reheated.
     
     
    Energy Consumption
  • High
  • Very Expensive
  • Less Efficient Heating System.
  •  
    Comfort
    • Rapid response to temperature variations.
    • Dry air (humidity need to be replaced).
    • Constant air circulation in room.
    • Uneven heat; large variations in air temperature.
    • Cold Floor and hot ceiling. Noisy.
    Safety
    • Open Heating Elements (high temperature).
    • Dust and/or dirt on the heating element can be a fire hazard.
    • No GFCI protection.
    • Heating elements accessible to children.
    • Materials close to baseboard can be a fire hazard.
    • Furniture can be damaged by baseboard heating.
    Maintenance
    • Regular Cleaning of Baseboard.
    • Cleaning or Replacement of Heating Element.
    • Increased Dusting of Furniture.
    Installation
    • Screw the baseboard to wall.
    • Connect thermostat.
    Cost
    • Not Expensive.
    • Needs maintenance.
    • Limited Life.

    Forced AirForced Air

    Air is heated in a furnace and pushed into the house through a duct system. Cold air is sucked up from different locations in the house and reheated in the furnace.
     
     
    Energy Consumption
  • High
  • Relies on Fuel Cost
  • Consumption 80%
  • Fuel Oil only 65 % efficiency.
     
     
    Comfort
    • No "Zone" control. Dry air (humidity needs to be replaced).
    • Constant air circulation in room.
    • High dust Circulation. Noisy.
    • Can be used for air conditioning.
    • Very slow reaction to cold air draft (open doors).
    • Odors fuel oil etc... can be transferred to the entire house.
    • Health hazards caused by dirty ducts.
    Safety
    • Dust and/or dirt on the heating element can be a fire hazard.
    • Neglected maintenance or burner can be a fire hazard.
    • Gas and oil leaks can be a fire hazard.
    • Health hazards caused by dirty air ducts.
    Maintenance
    • Yearly Replacement of Filters.
    • Yearly Replacement of Heating Elements or Burners.
    • Regular Cleaning of Conduits.
    • Regular Maintenance of Ventilation System.
    Installation
    • Install fuel reservoir.
    • Connect to gas supplier. Install furnace.
    • Install duct system.
    • Install thermostat.
    • Calibrate system.
    Cost
    • Very Expensive.
    • Needs yearly maintenance.
    • Repairs are often expensive. Components need to be replaced.

     

    Evaluation

    UUDAF Definition of a Comfort Zone

    UUDAF is a comfort evaluation chart used by Centre Scientifique et Technique du Bâtiment from France.

    Horizontal

    Uniformity of the temperatures

    Vertical

    Uniformity of the temperatures

    Without Radiation

    Draft (air movement within the room)

    Asymmetry

    Floor cold or warm.

     

    WARMSURFACES, meets all the requirements of UUDAF

    U:

    The heat distribution is even from one wall to the other.
    WARMSURFACES is laid down on the entire area of the floor.
    Each square inch of floor generates comfort.

    U:

    Temperature variations from top to bottom should be minimal.
    WARMSURFACES does not heat the air of the room thus eliminating air stratification, warm air at the ceiling and cold air on the floor.

    D:

    The room is heated without an air draft created or resulting from convection.
    WARMSURFACES does not use the air to heat the room thus eliminating air movement within the room (draft).

    A:

    Heat radiance is balanced within the room.
    Each square foot of WARMSURFACES generates 12 Watts of comfort.

    F:

    The floor cannot be cold nor hot.
    The temperature of WARMSURFACES is controlled by a thermostat or a dimmer.
    The floor is always comfortable.

     

    Evaluate your own heating system!

    If your heating system has all of those criteria, it is a good floor heating system.
    If it is misses 1, you have a little discomfort, but it still is a good system.
    If it is misses 2, or more of those requirements, your heating system is uncomfortable.
    Let WARMSURFACES be part of your space and your comfort.
     
     
    Thermostat
  • Control the degree of comfort that suits you

  • WarmSurfaces uses Class A thermostat Only ( Ground Fault Circuit Interrupter) , this thermostat is also  an electronic on/off thermostat for control of temperature by means of a sensor either placed externally or build into the thermostat. It has a build in clock function for automatic comfort and setback.

     

    WarmSurfaces Generates 12 watts of comfort per square foot of flooring (120 w/square foot). The thermostat will preset your personalized comfort. While saving electricity and money.

     

    WarmSurfaces comes as a heating cable. a heating mat, or a combination of both. It heats safely, with less that the minimum acceptable emissions of EMF (electromagnetic field).

     

     

     

    Can WarmSurfaces be installed on hardwood floors?
    It is an electric wire chosen for its heating properties, when a current is applied to it. The cable is placed on the surface of the floor with spacing of three inches. The cable emits 12 watts of heating per square foot of surface. A thermostat controls the temperature of the floor. The thermostat reads the temperature of the thought a probe that is on the floor, which allows adjusting the temperature of the floor according to your preference. Like the sun, the floor emits rays of heat that will warms the furniture, the walls and the people in the room, each person absorbs the heat according to their needs and everyone is comfortable. The temperature in the room will be 1 or 2 degrees lower than that of the floor.
     
     
    How much does WarmSurfaces cost and who can install it?
     
     
    Can it be installed on hardwood floors? 
     No, this is because there is a risk that the wood can dry and warp as a result of the heat.
    No, and because the hardwood floor must be nailed in, thus the nails can harm the cable.
     
    How much does WarmSurfaces cost and who can install it?

    How much does it cost and who can install it?

     

    At purchase the price is set according to the surface coverage.
    At use consumption is reduced by 30 % than with heating plinth.
    This is because radiating heat is much more effective, it consumes less  energy for the same cost. Consumption is equal to other heating systems.
    It can be installed by construction workers, many floor installers, and electrician, however, the racordement of the floor must be done by an electrician, because it is an electrical device.

     

    Will WarmSurfaces be enough to heat the room?
     
     
     
     
     

                            

    If I have too much cable can I cut it? 

    No, it is dangerous to shorten the cable; this can lead to a fire.
     
    enough to heat the room
     
    Will it be enough to heat the room? 

    Yes. In North America, we have a need of 10 Watts per square foot of flooring to be comfortable. We generate 12 watts per square foot, thus you will have all the heat that you will need.

     
     
    Can I connect a 120-volt cable on 240 volts? 
    No, the cable will burn.
     
     

    What do I do if the cable breaks?

    If the cable is broken before the floor covering is applied, it can be repaired easily, we have a repair kit.

    If the cable breaks after the floor covering is applied, there are specialists that can localize the break and repair it.

    The floor cover protects the cable, it is in concrete, and it only serves to heat, thus there is no reason for the cable to break. This is guaranteed.
     
     

    Can I use my own Thermostat?

    You can use any thermometer, on the condition that it reads the temperature of the floor and not that of the air in the room.
    If you use a wall thermometer the floor would become to hot for some time and very cold when its not heating.

     
    Where can it be installed? 

    Warm Surfaces can be installed in a bathroom, kitchen, basement, anywhere we want to be comfortable... on plywood.
    On Concrete... ceramic marble, granite, or slate tiles, as well as wooden floors, vinyl tiles, or carpets.

     

    Where can it be installed? Where can it be installed?

     

     

     
     
     

    Installation Manual 

  • Recently Viewed Items
    19 sq.ft  120 Volt  Warm Surface , Radiant Floor Heating System
    19 sq.ft 120 Volt Warm Surface , Radiant Floor Heating System
    C$175.00
    180 GPD REVERSE OSMOSIS TFC FILLIT MEMBRANES
    180 GPD REVERSE OSMOSIS TFC FILLIT MEMBRANES
    C$110.00C$89.00
    175 sq.ft  240 Volt Warm Surface , Radiant Floor Heating System
    175 sq.ft 240 Volt Warm Surface , Radiant Floor Heating System
    C$488.00
    150 sq.ft  240 Volt Warm Surface , Radiant Floor Heating System
    150 sq.ft 240 Volt Warm Surface , Radiant Floor Heating System
    C$438.00
    Browse Similar Items
    Under Floor Heating
    Under Floor Heating > RETURN WIRE TYPE

    Spun Polypropylene Sediment Filter 1 Micron, size 10
    11
    9 Stage Alkaline Reverse Osmosis System + Ultra Violet Philips UV
    Reverse Osmosis  Carbon GAC + Carbon Inline  + Sediment Filters Size 10
    2
    8 STAGE ALKALINE MINERAL INFRARED REVERSE OSMOSIS SYSTEM 50GPD
    Fitting - 1/4 tube O.D x 1/4 NPT Elbow
    50 GPD REVERSE OSMOSIS TFC FILLIT MEMBRANES
    Electro-Air Media Filter M1-1056 Air Filter
    Electro-Air Media Filter M8-1056 Air Filter
    Flat Double-layered filter - PP sediment + GAC two in one stage filter size 10
    Pleated Filter 1 Micron, size 20
    6 STAGE RE-MINERALIZATION 50 GPD REVERSE OSMOSIS WATER SYSTEM
    Bracket for 1 Stage 10 or 20
    CTO Carbon Block Filter size 10
    DI Deionization Mixed Bed Ion Exchange Resin / Demineralization Filter
    In-Line 2
    Pleated Filter 1 Micron, size 10
    Spun Polypropylene Sediment Filter 5 Micron, size 20
    10 standard Housing Wrench
    3 sets Reverse Osmosis Water Filters + 75GPD membrane
    5 Stage 75 GPD Reef Aquarium Reverse Osmosis System + Float Valve RO DI
    8 STAGE ALKALINE MINERAL INFRARED REVERSE OSMOSIS SYSTEM QUICK TYPE SYSTEM
    Digital PH Meter Pen ( One Touch )
    HM Digital ZT-2 Basic Handheld Meter Without Carrying Case
    Reverse Osmosis 4  Filter sets / 4 changes
    Reverse Osmosis Check Valve Elbow 1/4

    MAX WATER
    # 6,  51 A Caldari Rd
    Concord, ON. L4K 4G3 CA
    info@maxwaterflow.com