Reverse Osmosis Side-Mount Booster Pump Kit 200 GPD Complete Package
100 GPD Reverse Osmosis Booster Pump Kit
Improve the operating pressure and performance of your residential reverse osmosis system with this complete 24V 100 GPD RO booster pump kit. Designed for reverse osmosis membranes rated up to 100 GPD, this pump is ideal for homes with low municipal water pressure, well-pressure systems, slow storage-tank filling, or continuous drain-water flow caused by insufficient feed pressure.
By increasing the pressure supplied to the RO membrane, the booster pump helps improve membrane efficiency, supports more consistent purified-water production, and reduces the time required to refill the RO storage tank.
The complete booster pump kit arrives preassembled on a mounting bracket and includes the electrical and plumbing components required for a standard installation. It is ready to connect to a compatible residential reverse osmosis system.
Reverse osmosis system not included. Any RO system shown in additional product images is provided only to demonstrate how the booster pump bracket can be installed.
Included Components
- 24V DC 100 GPD reverse osmosis booster pump
- 24V DC transformer
- Two 1/4-inch tube OD fittings are included for the pump inlet and outlet connections.
- High-pressure shut-off switch
- Pump mounting bracket
- T-connector
- Preassembled booster pump configuration
Key Features
- Designed for residential RO membranes rated up to 100 GPD
- Low-voltage 24V DC operation
- Transformer included
- Helps improve RO membrane operating pressure
- Supports faster storage-tank refill under low-pressure conditions
- Helps improve membrane efficiency and purified-water production
- Compact, preassembled mounting bracket simplifies installation
- Pump duty cycle varies according to system load, feed-water pressure, ambient temperature, and installation conditions
- Approximate product weight: 4.5 lb.
- Approximate dimensions: 5 in. × 4 in. × 11 in.
When a Booster Pump Is Recommended: Consider this booster pump when incoming water pressure is below approximately 50 PSI, when your property uses a well-pressure tank operating around 40–60 PSI, when the RO storage tank takes more than two hours to fill, or when the system continuously sends water to the drain because the operating pressure is too low.
When This Booster Pump May Not Help: Customers with stable city-water pressure of approximately 55 PSI or higher may not experience a meaningful increase in RO production from this pump.
This booster pump is not designed to increase delivery flow from the RO faucet, refrigerator, or ice maker. For that purpose, you normally need a separate RO delivery pump or demand pump.
Please contact us before ordering if you are unsure which type of pump your system requires.
Specifications
| Specification | Details |
|---|---|
| Model / Item Number | 100 GPD |
| Nominal Flow | 1.30 L/min. |
| Operating Pressure | 70–100 PSI |
| Electrical Rating | 24V DC, 1.2A |
| Recommended RO Membrane Capacity | Up to 125 GPD |
| Approximate Weight | 4.5 lb. |
| Approximate Dimensions | 5 in. × 4 in. × 11 in. |
Product Appearance Notice: Product labels, colours, housing styles, fittings, and minor visual details may vary according to supplier and production batch. All supplied units are intended to meet the advertised specifications and performance requirements.
Recommended Upgrades and Accessories
Option 1: Add a Low-Pressure Safety Switch
Highly recommended for additional pump protection. The low-pressure safety switch automatically shuts off the booster pump when the incoming water supply is interrupted or the feed pressure drops too low.
This helps prevent the booster pump from running dry, overheating, or suffering premature motor damage.
Recommended for:
- First-time RO installers
- Homes with occasional water interruptions
- Well-water systems with variable feed pressure
- Customers who want additional pump protection
- Installations that may receive limited monitoring or maintenance
- Helps prevent dry-running damage
- Helps protect the booster pump from overheating
- Helps extend booster-pump service life
- Provides inexpensive protection against pump replacement costs
Option 2: Add a 24V Solenoid Valve
Recommended for booster-pump systems without a compatible automatic shut-off valve.
The 24V solenoid valve works with the booster pump controls to stop incoming water when the RO storage tank is full. This helps prevent unnecessary water from continuously passing through the RO membrane and flowing to the drain.
In certain booster-pump configurations, an automatic shut-off valve alone may not completely stop the incoming water. As a result, city water may continue flowing through the system and discharging to the drain after the storage tank is full.
- Helps prevent unnecessary drain-water flow
- Automatically shuts off inlet water when the storage tank is full
- Improves overall RO-system control
- Helps reduce avoidable water waste
- Helps reduce water and utility costs
Need help selecting the correct configuration? Confirm your incoming water pressure, RO membrane capacity, and whether your system already has an automatic shut-off valve before placing your order.