ULP 4040 2600 GPD Commercial Reverse Osmosis RO Membrane / Used In good condition, Tested
BW 4040 HF 2400 GPD Commercial RO Membrane -Used (Very Good Condition) 98% Rejection
This membrane was purchased in error and returned by the customer. It has been barely used and is in very good condition, ideal for commercial RO systems requiring high flow performance.
ULP-4040 2600 GPD Commercial RO Membrane
- Reverse Osmosis membrane elements for commercial drinking water systems are the industry's most reliable method of water filtration. Advanced membrane technology and automated fabrication allow these elements to deliver consistent performance that equipment suppliers, water treatment dealers, and residential customers can rely on. Our Reverse Osmosis membranes are shipped dry for convenient handling and long shelf-life. Our ISO9001-rated membranes are rated at 60 psi and will purify about 20% more water than competitive elements rated at 60 psi.
- ULP-4040 standard flow is 2600 GPD @ 150 PSI. Now, if you reduce pressure to city water to 60 to 80 PSI, pressure is reduced; therefore, permeate flow will be approximately 1040 to 1400 GPD according to the incoming low pressure you apply
We suggest changing your membrane every 2 years
Specifications
- 2600-gallon per Day Membrane for Commercial Reverse Osmosis systems.
- Certified to ISO 9001 Standards
- Removes particles down to 1/10,000th of a micron (removing 98% of impurities including organic, inorganic contaminates, chemicals, ETC.).
TDS = Total Dissolved Solids.
Membrane Features
- Provides stable, high rejection of contaminants even with high TDS water sources.
- Advanced membrane technology with innovative thin-layer composite membrane design.
- More consistent performance with less fouling requiring less frequent cleaning and changeouts.
- 100% dry-stored membrane maximizing shelf life.
- Best-in-Class Membrane Quality – Engineered with 90 ft² (8.36 m²) active membrane area to deliver maximum output, durability, and long-lasting filtration performance.
General Information
- The first full tank of permeate should be discarded. DO NOT use this initial permeate for drinking water or food preparation as it may contain carbon fines and manufacturing by-products.
- Keep membrane moist at all times after initial wetting.
- To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.
- The membrane shows some resistance to short-term contact with chlorine (hypochlorite). Continuous exposure, however, may damage the membrane and should be avoided.
- If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.
Usage
It is widely used for automatic water dispensers in residential areas and schools, direct drinking equipment in offices, pure water machines in medical laboratories,small-sized desalination devices etc.
Specifications & Parameters
| Model | Active Membrane Area ft2(m2) | Permeate Flow GPD(T/D) | Stable Rejection Rate (%) |
| ULP-4040 | 90(8.36) | 2600(9.8) | 99.35 |
Standard Test Condition
| Concentration of Solution (NaCl) | Temperature(?) | pH Value | Operating Pressure psi(MPa) | Recovery Rate (%) |
| 1500ppm | 25 | 7.5-8 | 150(1.03) | 15 |
Notes: The permeate flow of a single membrane element may vary within ±15%.
Operating Limits and Conditions of Membrane Element:
| Max.Working Pressure | 600 psi(4.14MPa) |
| Max. Feedwater Temperature | 45 ? |
| Max. Feed Water Flow | 3.6m3/h |
| Max. FeedWaterSDI15 | 5.0 |
| Free Chlorine Concentration of Feed Water | 0.1mg/L |
| PH Range of Feed Water During Continuous Operation | 2-11 |
| PH Range of Feed Water During Chemical Cleaning | 1-13 |
| Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) |
ULP-4040 Reverse Osmosis Membranes for many Applications such as:
- Car Washes
- Whole House Reverse Osmosis
- Commercial Reverse Osmosis
- Agricultural
- Industrial
Commonly referred to as Extra Low Pressure, Extra Low Energy, Ultra Low Pressure, or Ultra Low Energy
4" x 40" Fits nearly all standard 4" x 40" Membrane housings, stainless steel, PVC, or Fiberglass
Filter Replacement Options and Alternatives for Item Number:104293-U
Your Price: 950.00
Part Number: 105530
In Stock
Sale
Part Number: 105884
In Stock