2300 to 2500 GPD Commercial-Grade Reverse Osmosis System -  Maple Syrup , Beer Brewing  Production
2300 to 2500 GPD Commercial-Grade Reverse Osmosis System - Maple Syrup , Beer Brewing Production

2300 to 2500 GPD Commercial-Grade Reverse Osmosis System - Maple Syrup , Beer Brewing Production

CAD $6,000.00
CAD $4,675.00
  (Saving:22%)
Part Number: 101138~104293
In Stock

Choose Options

ADD Iron System
None
ADD Iron System #103191~104121 (220.00)
*We'll ask for shipping info at checkout

2300 to 2500 GPD Commercial-Grade Reverse Osmosis System - Maple Syrup , Beer Brewing Production

The 2300 GPD Commercial-Grade Reverse Osmosis System is designed for whole-house, commercial, manufacturing, agricultural, and industrial water purification applications.

Engineered specifically for maple syrup production, this high-efficiency RO system can produce up to 2,300 gallons per day when equipped with an XLP-4040 membrane. It helps concentrate maple sap before evaporation, significantly reducing boiling time, fuel consumption, energy use, and overall production costs.

For general water-treatment applications, the system can be configured with a ULP Ultra Low Pressure membrane, increasing production capacity to approximately 2,500 GPD. The ULP configuration operates at a lower pressure, helping improve energy efficiency and reduce operating costs.

Actual production capacity will vary depending on feed-water quality, water temperature, operating pressure, membrane type, membrane condition, and the concentration of the incoming maple sap.


Included Components

  • Fully automated 2300 GPD commercial maple syrup reverse osmosis system, rated for 110 V, single-phase, 60 Hz operation.
  • One XLP-4040 extreme low-pressure RO membrane: Part No. 104303 .
  • One 20-inch x 4.5-inch two-stage whole-house prefiltration system for treating incoming water or maple sap before it enters the reverse osmosis system.

Production Capacity: System output depends on membrane type, feed-water temperature, operating pressure, membrane age, membrane condition, and maple sap concentration. When equipped with the XLP-4040 membrane , production may range from approximately 1,500 to 2,300 GPD when processing maple sap.

Pump Protection: If the incoming water or sap contains iron, manganese, sulfur, hydrogen sulfide, sediment, or other contaminants, additional prefiltration is strongly recommended. Proper pretreatment helps protect the rotary pump and RO membrane from premature wear, fouling, and performance loss.

A recommended optional filter is the 103191–104121 20-inch x 4.5-inch Big Blue iron, manganese, sulfur, and hydrogen sulfide filter .

UV Sterilization: If the feed water is not chlorinated, adding a UV sterilizer is recommended to help control bacteria and biological growth inside the RO system.

Recommended option: Part No. 105045 – 12 GPM Whole-House UV Sterilizer.

Suitable Applications: Maple syrup production, whole-house water purification, light commercial operations, hotels, hospitals, restaurants, car washes, hydroponics, agriculture, apartment buildings, factories, textile production, cosmetic manufacturing, and other commercial water-treatment applications.

Recommended Pump Protection: To extend the life of the multistage pump and reduce frequent starting and stopping, we recommend using the 105050 Liquid Level Control Switch .

This control switch provides more reliable tank-level management than a basic electronic float valve and helps reduce unnecessary pump cycling.

Feed-water pump is not included and must be purchased separately.


System Specifications

2300 GPD commercial reverse osmosis system specifications

Parts Description

Item Specifications
Power Control 4-position control with indicator light
RO Controller Integrated TDS monitor
Pressure Regulator 1/2-inch SUS316 fixed-type regulator
Raw-Water Inlet Pressure Gauge Embedded type, 7 kg/cm², 100 PSI, 2.5-inch diameter
RO Outlet Pressure Gauge Embedded type, 35 kg/cm², 500 PSI, 2.5-inch diameter
RO Membrane Vessel and End Caps Stainless-steel vessel body with polypropylene end caps
Magnetic Starter 200 V, 9–12.5 K
RO Pump MM1 80MC/4
Inlet Valve 3/4-inch SLP20E2
Low-Pressure Switch LF-20, 1/4-inch connection

Required Inlet-Water Quality

Parameter Required Feed-Water Condition
Minimum Feed-Water Pressure Greater than 1.5 kg/cm²
Water Hardness Less than 50 ppm as CaCO3
Turbidity Less than 1 NTU
TDS = Total Dissolved Solids. Less than 1,000 ppm
Free Chlorine Less than 0.1 ppm

TDS = Total Dissolved Solids.

Recently Viewed Items